Products

 

All Category   »  Environmental & Safety   »  Indoor Air Quality Monitoring   »  Gas Detector   »  Low Power Detector

LPT

 

Product Detail

 
 
 
 

LPT

For monitoring: Ammonia, Carbon monoxide, Nitrogen dioxide, Chlorine, Ozone or Oxygen
 

LPT-A

For monitoring: Ammonia, Carbon monoxide, Chlorine dioxide, Chlorine, Ethylene, Ethylene oxide, Fluorine, Formaldehyde, Hydrogen, Hydrogen sulphide, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs, Refrigerants
 

LPT-P

For monitoring: Carbon monoxide, Nitrogen dioxide, Methane, Propane, Hydrogen
 

LPT-M

For monitoring: Ammonia, Carbon monoxide, Chlorine dioxide, Chlorine, Ethylene, Ethylene oxide, Fluorine, Formaldehyde, Hydrogen, Hydrogen sulphide, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs
 

LPT-B

For monitoring: Ammonia, Carbon monoxide, Chlorine dioxide, Chlorine, Ethylene, Ethylene oxide, Fluorine, Formaldehyde, Hydrogen, Hydrogen sulphide, Hydrogen chloride, Hydrogen cyanide, Hydrogen fluoride, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Phosphine, Silane, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs
 

CXT-1

For monitoring: Ammonia, Carbon monoxide, Nitrogen dioxide, Oxygen, Hydrogen sulphide, Sulfur dioxide, Methane, Propane, Hydrogen, Butane, Ethanol, Hexane, Toluene, Pentane, Ethylene
 
 

Mechanical
Enclosure ABS / Polycarbonate, corrosion resistant Copper coated interior to reduce RF interference IP54 rated with splash guard installed
Weight 363 g / 0.8 lbs
Size 127 x 127 x 53 mm / 5.0 x 5.0 x 2.1 inches

User Interface
Display Graphic LCD, grey border
Magnetic switches to initiate calibration without opening the enclosure

Input/Output
Output Linear 4 - 20 mA analog
Maximum 216 Ω load (wiring plus termination resistor) @ 12 VDC
Maximum 316 Ω load (wiring plus termination resistor) @ 12 VAC
Voltage 0 - 10 volt
Minimum 1k ohm load
Relay
1 SPDT dry contact, rated 30 Volts, 2 Amps max
Audible Alarm
Standard internal buzzer

Electrical
Power Requirement
3-wire mode: 16-30 VDC, 3 W, Class 2
4-wire mode: 12-27 VAC, 50-60 Hz, 3 VA, Class 2
Current Draw
125 mA @ 24VDC (max)
Wiring
VDC (or ground referenced AC): 3-conductor 18 AWG stranded, shielded
VAC: 4-conductor 18 AWG stranded, shieldedFusesThermal, resetting

Environmental
Operating Temperature -20°C to 40°C (-4°F to 104°F)
Operating Humidity 15 - 90% RH non-condensing

Certifications

Conforms to
CSA-C22.2 No. 205-M1983 (R2009), UL508 (Edition 17):2007
EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010
FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RoHS compliant circuit boards

  • Parking Facilities
  • Vehicle Repair Shops
  • Arenas and Pools
  • Refrigeration Rooms
  • Chiller Rooms
  • Battery Charging Rooms
  • Hotels
  • Airports
  • and many more...

  • Single channel, with internal or remote sensor options
  • Linear 4 - 20 mA analog or 0 - 10 volt output signal
  • LCD display
  • One 2A SPDT dry contact relay
  • Internal audible alarm
  • 3-wire VDC or 4-wire VAC power
  • 24 volt DC or AC power (nominal)
  • Unobtrusive calibration and menu navigation using a magnetic wand
  • Optional heater for cold environment applications
  • Standard water / dust tight, corrosion resistant enclosure (drip proof)
  • IP54 rated with optional splash guard installed

 

สนใจข้อมูลเพื่มเติมฝากรายละเอียดการติดต่อไว้ด่านล่างได้เลยค่ะ

 
 
Phone : 02-030-5852 | Email : sales@tasatec.com | Facebook : facebook.com/tasatec