Non-Invasive Level Switch

The Non-Invasive level switch is a new type of liquid level monitoring and alarming device. It is mainly used to monitor the liquid level of the storage tank, realize the upper and lower limit alarm or monitor whether there is a medium in the pipeline (dry state protection). It can be applied to the liquid level process control of medicine, petroleum, chemical industry, power, food, and other industries.

Additional information

Application

Chemicals, Food, Fuels, Petrochemical, Pharmaceutical, Refinery, wastewater, Water

Measure Component

level switch, Non-Invasive Level Switch, Point Level Measurement

Description

The Non-Invasive level switch is a new type of liquid level monitoring and alarming device. It is mainly used to monitor the liquid level of the storage tank, realize the upper and lower limit alarm or monitor whether there is a medium in the pipeline (dry state protection). It can be applied to the liquid level process control of medicine, petroleum, chemical industry, power, food, and other industries.
  • High/Low Position alarm
  • Alarm position – At any place required. Not limited by fixed hole on the side wall.
  • Non-contact with the liquid inside.
  • No maintenance, not influenced by (exp: thick oil deposits).
  • No tank break in; Non-side drilling; No flange
  • No shutdown/empty tank during installation.
  • Local Alarm & Display/Relay output to PLC

Technical specifications

PowerDC 24V
Signal OutputRelay Output (passive node)
Relay capacity(DC 30V 6A ) 、( AC 250V 6A)
Repeatability error±5mm
Container Wall ThicknessMax 60mm
Container MaterialSteel, stainless steel, glass, non foaming plastic and other dense materials
Measurable mediumPure liquid, emulsion liquid, suspension liquid
Ambient temperature-20℃~+70℃
Ambient humidity(0%~95%) RH
Rated Power3W
Transmitter MaterialCast Aluminum
Protection RatingIP67
Electrical ConnectorM20 X 1.5
Hazardous Area ApprovalExdIICT6
Weight 2 KG
DimensionLength158mm×Width122mm×Height148mm

Petrochemical
Food
Chemicals
Fuels
Water
wastewater
Pharmaceutical
Refinery

  • 2-wire 80GHz FMCW Radar
  • For liquid and bulk solids.
  • High Frequency 80GHz, More Focus
  • Beam Angle 3°
  • One type of PTFE Antenna, no cable, rod, or drop structure.
  • Suitable for long/tall/narrow applications
  • Not affected by temperature changes, dust or vapors
  • Dielectric Constant > 2 is recommended
  • Support small batch OEM service

No Accessories data.

No Media Data.

Additional information

Application

Chemicals, Food, Fuels, Petrochemical, Pharmaceutical, Refinery, wastewater, Water

Measure Component

level switch, Non-Invasive Level Switch, Point Level Measurement

หากลูกค้าสนใจสินค้าหมวดหมู่

Non-Invasive Level Switch

สามารถติดต่อเราได้ที่นี่