LPT-B BACnet® Transmitter

LPT-B BACnet® Transmitter

เซนเซอร์ตรวจจับแก๊ส ที่ส่งสัญญาณแบบ BACnet สำหรับการสื่อสารในอาคารสมัยใหม่ได้เลย

For monitoring: Ammonia, Carbon monoxide, Chlorine, Ethylene, Formaldehyde, Hydrogen, Hydrogen sulphide, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Sulfur dioxide, Methane, Propane, Hydrogen, TVOCs

A full featured, 3 channel, digital (BACnet®) gas detector with many gas sensor choices, intended to be used alone or integrated into an existing BACnet® network

Additional information

Application

Air Quality

Measure Component

gases, refrigerants, TVOC

Description

The LPT-B is a full featured, 3 channel, BACnet® transmitter for use in non-hazardous, non-explosion rated, commercial and light industrial applications. It is available with a wide range of internal and/or external sensors and sensor types including electrochemical, catalytic and PID TVOCs.

The LPT-B may be configured to operate as a standalone fixed system or be part of a digital network. It offers a BACnet® MS/TP output signal for communicating with a Controller or Building Automation System, an audible internal alarm, one SPDT dry contact relay, LCD display with user selectable functions, temperature compensation and thermal resetting fuses all in a RoHS compliant package.

The LPT-B comes in a standard water / dust tight, corrosion resistant ABS / polycarbonate enclosure with a hinged, secured door. It is IP54 rated with the optional splash guard installed which provides protection in water spray or wash down applications.

Mechanical
Enclosure
ABS / Polycarbonate, corrosion resistant
Copper coated interior to reduce RF interference
IP54 rated with optional splash guard installed
Weight
363 g / 0.80 lbs
Size
127 x 127 x 71 mm / 5.0 x 5.0 x 2.8 inches
User Interface
Display
Graphic LCD, yellow border
Magnetic switches to initiate calibration without opening the enclosure
Input/Output
Output
BACnet® MS/TP communications
Relay
One SPDT dry contact, rated at 30 volts, 2 amps max
Audible Alarm
Standard internal buzzer, enable/disable, rated 90 dB @ 10 cm / 4 in
Electrical
Power Requirement
16-30 VDC, 3 W, Class 2
12-27 VAC, 50-60 Hz, 3 VA, Class 2
Current Draw
55 mA (buzzer & relay energized, 2 sensors)
Wiring
4-conductor, 16 AWG stranded, shielded network wiring (daisy-chain)
Fuses
Thermal, resetting
Environmental
Operating Temperature
-20°C to 40°C (-4°F to 104°F)
Operating Humidity
15 – 90% RH non-condensing
Certifications
Conforms to
CSA-C22.2 No. 205-12 / UL508 (Edition 17):2007
EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010
FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Listed by BTL
RoHS compliant circuit boards
  • Parking Facilities
  • Arenas and Pools
  • Chiller Rooms
  • Manufacturing Plants
  • Maintenance Facilities
  • Food Processing Plants
  • Ice Cleaning Machine Rooms
  • 1, 2 or 3 channel operation with internal and/or remote sensor configurations
  • BACnet® MS/TP communication
  • LCD display
  • One 2A SPDT dry contact relay
  • Internal audible alarm
  • 24 VAC/VDC power
  • 4-conductor daisy chain network wiring
  • Unobtrusive calibration and menu navigation using a magnetic wand
  • Standard water / dust tight, corrosion resistant enclosure (drip proof)
  • IP54 rated with optional splash guard installed.