Factors Affecting Static COF Reproducibility

มาดูกันว่า อะไรทำให้ Static COF มีความไม่แน่นอน Factors Affecting Static COF Reproducibility

สิ่งเหล่านี้ คือสาเหตุที่ทำให้การทดสอบหาค่า COF แบบ static มีค่าที่ไม่เสถียร ไม่แน่นอน

  • Differences in the speed of the sampling rate or number of force data points per second captured during static test time
  • Differences in the dwell time or seconds from the time the sled is placed on the sample until the sled movement begins. The longer the time the sled is resting on the sample, the higher the static COF.
  • Applying too much positive or negative force against the load cell when placing the sled on the sample before testing
  • Zeroing the instrument after placing the sled on the substrate before testing. Do not adjust the zero reading after placing the sled on the sample.
  • Condition of the rubber surface area of the sled. Check the outer edges of the rubber, evaluate if the edges are worn. If the area of the rubber is reduced from wear, then the static kinetic friction result will be lower.
  • Changes in durometer hardness of the rubber between sleds
  • Differences in the surface topography/roughness of the base plate
  • Sample pressure and placement of the sled before the test begins
  • Rubbing the sled and sample against each other before the test begins
  • Differences in the acceleration speed at the start of the test
  • Ageing of the material